EMERGENCY KIT FOR DC LED LAMPS

ID code:



PRODUCT DETAIL - CHI TIẾT SẢN PHẨM

Caution:

1. Reverse charging is not acceptable.

2. Charge before use. The battery is delivered in an half-charged state.

3. Do not short circuit the battery.

4. Do not incinerate or mutilate the battery.

5. Do not solder directly to the battery.

6. The life expectancy may be reduced if the battery is subjected adverse conditions like: extreme temperature, deep cycling, excessive over-charge/over-discharge.

7. Store the battery in a cool dry place.

8. Warning: Lsw (Switched Supply), Lun-sw (Un-switched Supply) and N as marked, not interchangeable and must be of the same phase as ELCB.


TECHNICAL INFORMATION – THÔNG SỐ KỸ THUẬT

 

Input voltageSingle phase AC 100-240V

Output voltageDC 10-80V

Frequency50/60Hz

BatteryNi-Cd 6V

Charge time24 hours 

Emergency time2hrs

Operating temp0~50°C

IP gradeIP20

Dimension of inverter29x40x206mm

Dimension of batterCustomized

Light sourceMax 100W LED Light with Internal or External Driver

Emergency powerMax 6W

Work modeMaintain/Non-Maintain

Indicator lightRed for Charging/Green for Power/Yellow for Trouble

Test facilityPush botton switch

Protection fittingOver-Charge/Over-Discharge

ConstructionFireproof Polycarbonate (PC) housing

ComplianceEN 61000-6-3 : 2001 61000-6-1 : 2001; CE; RoHS